Avail in 75, 150, 225, 300, 375, 450, 525 & 600 capacities
SPECIFICATIONS FOR CELLS SUPPLIED IN POWERPACKS
Cells used in Lithium power Strap pack units are CALB L135F72
- Qualified for RoHS & CCC with high safety
- More than 3000 cycles under the designed working condition
- Integral safety valve is used to enhance safety
- Ceramic membrane technology applied to enhance safety
- Aluminium shell for better cooling
- High energy density, 121WH/Kg
- High charge/discharge rates
- Nominal Capacity @ 0.3C 72 Ah
- Nominal Voltage 3.2 V
- Internal Impedance @ 1 kHz AC ≤ 0.6 mΩ
- Weight 1.9 kg
- Life Cycle @ 0.3C, 80% DOD 2,000 cycles, 70% DOD 5,000 cycles.
- Maximum Charging Current 72A
- Maximum Constant Discharging Current 216A
- Charging Cut-off Voltage 3.65 V
- Discharging Cut-off Voltage 2.5 V
- SOC Usage Window 10% ~ 90%
- Charging Temperature 0℃ ~ 45℃
- Discharging Temperature -20℃ ~ 55℃
- Storage Temperature within 1 month -20℃ ~ 45℃
- Storage Temperature within 1 year -20℃ ~ 20℃
LITHIUM POWER, POWERPACK SPECIFICATIONS12V-75AH > 600AH
- Voltage 12 V
- Nominal Capacity 75Ah > 600Ah
- Weight Approx 9kg > 65Kg
- Dimensions 170 x 150 x 295(H)mm (75Ah) > 560 x 300 x 296(H)mm (600)
- Terminals 20 x 3 tab wiith 8mm hole, optional Anderson plug or thumb screws.
- Operating temperature 0°C to +45°C
- Storage temperature -20°C to +45°C
- Charge type CC/CV
- Quick charge current 75A
- Quick discharge current 216A
- Max operating discharge current 750A
- Max pulse discharge current (<10s) 750A
- 75A Discharge capacity >90% capacity
- Minimum Voltage 10V
- Maximum Charge Voltage 14.6 V
Expected life span, After discharging 80% of capacity 2000 cycles, 80% of capacity still remains.
Full battery management including cell balancing, high & low voltage cutout.
High current fuse fitted in case of crowbar short.
Manual output switch to isolate nattery during connection or storage.
Voltage display showing total voltage and cell voltage with low voltage warning.